Comnet CWGE2FE8MSPOE Información técnica Pagina 136

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 143
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 135
129
AC Disconnect: Tick this checkbox to monitor the AC impedance on the port terminals
and removes power when the impedance rises above a certain value, for a certain
period (for details, see the IEEE 802.3af specification).
Capacitive Detection: If the port and capacitive detection are enabled, the
capacitances state reads in the voltage result from the constant current. This is then
subtracted from the pre-capacitance voltage to get a charge rate. If this charge rate is
within the window of the PD signatures, the device is considered to be discovered.
Start: Showing with a tick symbol, the system initializes and resets successfully.
And then, click to carry into effect.
Port: The index of PoE ports.
Enable State: Check it to enable the PoE function to the port.
Power Limit From: Check it to decide the power limit method.
Classification: When this check box is ticked, the system will limit the power
supply to the powered device in accordance with the related class.
Legacy: Check it to support the legacy power devices.
Priority: Pull down the selection menu item to choose the priority of power supplying.
Port Limit (<15400) mW: User can key in the power limit value that is under 15.4
Watts.
Mode: Displays the operating mode of the port.
Current (mA): Displays the operating current of the port.
Voltage (V): Displays the operating voltage of the port.
Power (mW): Displays the power consumption of the port.
Determined Class: Displays the PD’s class.
And then, click
to carry into effect.
Vista de pagina 135

Comentarios a estos manuales

Sin comentarios